Generators
DG set remote monitoring, from the meter to the engine.
See what your generator produced, how long it ran, how hard it worked and how the engine is holding up — energy, run hours, load, fuel and alarms in one place, from any site in Delhi NCR.
- DG kWh + run hours
- Load + power factor
- Fuel + engine data
- WiFi, Ethernet or 4G
How it works
One meter, two sources of data.
A service visit tells you how the generator looked on the day. Remote monitoring tells you how it behaved every hour in between — how many units it made, how long it ran, whether it was underloaded, and what the engine was doing when an alarm came up.
The monitoring is built on the Titan energy meter made by our group company Tech OVN. The meter measures the generator’s output itself, and its RS485 port reads the engine data from the genset controller. We fit it, wire it and hand it over as part of your service or AMC.
From the energy meter
How much the DG produced, and how hard it worked.
DG energy, kept separate
A 12 V signal from the generator tells the meter when the DG is running. While it is, kWh, kvarh and kVAh go into their own DG registers — so generator units are never mixed with grid units.
DG run hours
The meter records how long the generator actually ran, alongside the energy it produced in that time.
Load, power factor, voltage, frequency
Live kW and kVA against the DG rating, power factor, voltage and frequency per phase, harmonics and phase unbalance — the electrical side of how hard the set is working.
From your genset controller
How the engine is holding up.
Tell us your controller model and we confirm compatibility, and which values it exposes, before you order.
Engine condition
Oil pressure, coolant temperature, battery voltage and engine speed — whatever your genset controller exposes over Modbus.
Fuel level
Read from the controller's own fuel sensor. Put next to DG kWh, it shows units generated per litre and fuel that disappears while the set is not running.
Alarms and shutdowns
Warnings, shutdowns and failed starts as the controller reports them, time-stamped with the electrical data around them.
Connection
How the data leaves the DG room.
RS485 to the controller
Titan's RS485 port polls the genset controller as a Modbus master. In that role the port cannot also act as a slave to a BMS or SCADA — those systems take the data over the network instead.
WiFi or Ethernet
The standard Titan sends data over WiFi or Ethernet using Modbus TCP, MQTT or REST — into your own system or the Tech OVN platform.
4G for sites with no network
Titan 4G has a built-in 4G module and sends data over MQTT only. It needs an active data SIM. Suits DG rooms, rented sets and remote sites.
Which meter
Three Titan models.
Prices are Tech OVN list prices per meter. CTs are extra. Regular Titan orders ship from stock; lead time for Titan 4G is confirmed with the quote.
| Model | Connectivity | Price |
|---|---|---|
| Titan | WiFi + Ethernet + RS485 (Modbus RTU/TCP, MQTT, REST) | ₹11,000 + GST |
| Titan 4G | 4G (MQTT only) + RS485 | ₹11,500 + GST |
| Titan RS485 | RS485 only — energy and run hours into your own BMS; does not read the controller and send data out at the same time | ₹6,500 + GST |
Full specifications on Tech OVN: Titan · Titan 4G · generator monitoring system.
With your service
Monitoring plus the people who fix it.
Monitoring tells you something is wrong; it does not fix it. Pair it with a generator AMC or our service and breakdown team and your engineer arrives knowing the run hours, load history and alarm log. Response times are those of your service plan — under 4 hours for critical sites, 2 hours for hospitals and IT services companies on a Comprehensive AMC.
Running preventive maintenance yourself? Our diesel generator maintenance checklist and generator load test guide cover what to check and record.
Frequently asked questions
What does DG set remote monitoring show me?
Two things. From the energy meter: generator kWh, kvarh and kVAh in separate DG registers, run hours, load against the DG rating, power factor, voltage, frequency and harmonics. From your genset controller, read over RS485: engine data such as oil pressure, coolant temperature, battery voltage, engine speed, fuel level and alarms — whatever that controller makes available over Modbus.
Will it work with my generator's controller?
Most modern genset controllers have an RS485 Modbus port, but the data each one exposes differs. Tell us your controller model and we confirm compatibility and which values can be read before you order.
Where does the fuel reading come from?
From the fuel sensor already connected to your genset controller. If the controller has no fuel sensor, fuel level is not available — the energy and run-hour data still are.
Can it feed our BMS as well?
Yes, over the network: Modbus TCP, MQTT or REST on the WiFi/Ethernet Titan, or MQTT on Titan 4G. When the RS485 port is reading the genset controller it cannot also be a Modbus slave to a BMS, so plan the BMS link over the network.
Our DG room has no WiFi or LAN. What then?
Use Titan 4G. It sends data over a 4G connection using MQTT, so it needs an active data SIM but no site network.
How long does it take to get the meter?
Regular Titan orders ship from stock; Tech OVN confirms the lead time for Titan 4G with the quote. CTs are extra and are sized to the generator's rating.
Tell us the DG and the controller model.
We confirm what can be read, which Titan fits the site, and quote it with fitting.
